SlideBond TM Adhesive

Product images are for reference only and may vary from the actual product.

SlideBond TM Adhesive

For IHC/ISH/FISH

In Stock

Share Now :
  • SlideBond™ Adhesive is the gold-standard, covalent-bonding tissue adhesive for labs doing Immunohistochemistry (IHC), In-Situ Hybridization (ISH), and Fluorescence In-Situ Hybridization (FISH).
  • Normal slides and even “charged” slides fail in harsh IHC / FISH protocols because they use weak electrostatic attraction. Expensive biopsy tissue washes off during HIER (pressure cooker boiling), enzyme digestion (Proteinase K), and high-temperature hybridization (90°C).
  • SlideBond™ creates a permanent, chemical covalent bond between the glass slide and the tissue section. Once bonded, the section will NEVER detach, even after 4 hours of boiling and 24 hours of hybridization.

Why Labs Prefer SlideBond™ Over Poly-L-Lysine and Charged Slides?
  • Poly-L-Lysine: Only ionic bond, washes off in alkaline retrieval (pH 9.0) and during FISH. Also causes high non-specific background.
  • Commercial Charged Slides: Expensive, coating thickness varies batch-to-batch, and lose charge after 6 months.
  • SlideBond™ Adhesive: Covalent Si-O-Si bonding. Withstands pH 1 to pH 11, temperature up to 120°C, Proteinase K, Pepsin, and Formamide. IHC-compatible quality with a more competitive cost per slide, and coating lasts 2 years.
  • FISH / ISH / IHC Validated: Specifically optimized to withstand Pressure Cooker HIER (pH 6.0 & pH 9.0), Microwave retrieval, PT-Link, Proteinase K (15 min), Pepsin (30 min), and Formamide hybridization at 80-90°C.
  • Zero Background: Unlike Poly-L-Lysine, SlideBond is molecularly thin (monolayer) and does NOT pick up Hematoxylin or DAB, so background is crystal clear.
  • Ready-to-Coat Concentrate: 99% Pure SlideBond liquid – 50ml bottle makes 2.5 Liters of working solution = Coats 2500 slides. Ultra-economical.
  • Universal Compatibility: Works with ALL tissues – Bone decalcified with acid, brain, fatty breast, necrotic tumor, tiny endoscopic biopsies that detach easily.
  • Superior to Pre-Coated Slides: Freshly coated slides give 10x more adhesion than 1-year-old company-coated charged slides.
Covalent Bonding Chemistry
1. This is a 3-step chemical reaction, not just stickiness :

  • Step 1 – Activation: Glass slide surface has Silanol groups (Si-OH). When dipped in SlideBond, its Ethoxy groups (-OCH2CH3) react with Si-OH.
  • Step 2 – Silanization: It forms a strong, irreversible Siloxane Bond (Si-O-Si) with the glass. One end is now permanently anchored to the slide.
  • Step 3 – Amine Exposure: Amine group forms strong electrostatic and covalent cross-links with negatively charged tissue proteins (Carboxyl groups of tissue sections).
  • For IHC Lab :
    1. Never lose small biopsies again. Solves the #1 complaint: “Breast core / Prostate chip / GI biopsy washed off during retrieval.” Saves repeat biopsy requests and patient recall. Ideal for ER, PR, HER2 where re-cutting is mandatory.

  • For FISH / ISH / CISH Lab :
    1. This is the ONLY recommended adhesive for HER2 FISH, EBV ISH, ALK FISH. Sections stay intact after overnight hybridization at 37°C and harsh post-wash buffers. No more floating tissue during DAPI counterstain.

  • For Histology Lab :
    1. 1. Cost Saving: Significantly lower cost than commercial charged slides.
      2. Long Shelf Life: SlideBond Solution is stable for 3 years at 4-25°C. Coated slides stable for 2 years in dry box.
      3. Better Microtomy: SlideBond treated slides are slightly less hydrophilic, so sections flatten better and don’t wrinkle during pickup from water bath.

Related products

Recently Viewed Products

Scroll to Top

Where Histology meets certainty ….!

Office Address

849, Mouje Tasgaon,
Tal. Hatkanangale,
Dist. Kolhapur - 416122
Maharashtra, India.

phone number

+91 927 033 6969